مشخصات پژوهش

صفحه نخست /Optimizing the electrolyte ...
عنوان Optimizing the electrolyte chemistry parameters of PEO coating on 6061 Al alloy by corrosion rate measurement: Response surface methodology
نوع پژوهش مقاله چاپ‌شده در مجلات علمی
کلیدواژه‌ها Al alloy PEO Corrosion Nano-particles Response surface methodology
چکیده Different chemistry parameters of electrolyte, including KOH, Na2SiO3 and Al2O3 nano-particles concentrations were used to obtain the best coatings by plasma electrolyte oxidation (PEO). This work presents the formulation of a mathematical model based on chemistry parameters of electrolyte to predict the responses of corrosion behavior of PEO-coated 6061 Al alloy. In order to reach this goal, three compounds including KOH, Na2SiO3 and Al2O3 nano-particles in different concentration ranges were used and a response surface methodology was employed to develop the regression models. Analysis of variance was the method to determine the electrolyte chemistry that affects the responses. Approval trials were carried out to confirm these results. The results indicated that the lowest corrosion current density can be obtained at low concentrations (1–2 g/L) of KOH, high concentrations (5–6 g/L) of Na2SiO3, and moderate concentrations (2–4 g/L) of Al2O3 under the current conditions and process time employed in this particular study. Also, the study of microstructure and morphology of different coatings confirmed this electrolyte condition model. This condition led to an electrolyte with the best conductivity and oxidizing state, and highest contribution of electrolyte components in the coating growth process.
پژوهشگران مجتبی وکیلی ازغندی (نفر اول)، آرش فتاح الحسینی (نفر دوم)، محسن کشاورز خوراسگانی (نفر سوم)